Automatic reset, open on rise (normally closed) or close on rise (normally open)
Single pole, single throw (SPST)
Cost effective, compact, high reliability, long life, ROHS compliant
The sealed design provides moisture resistance for moisture prone environments.
Caratteristiche
Operating temperature range: 0~150℃ (32~302°F)
Temperature differentials : 8.5~55 K (difference between nominal off and on temperatures)
Temperature tolerance: ±3.0K, ±5.0K
Contact rContact resistance: 50mΩor less
Electrical Rating:
Electrical rating | Agency approvals | |||||
VDE | UL | TÚV | CQC | Life cycles | Remarks | |
AC125V/10A | ● | 100 K | Phenolic housing | |||
AC125V/16A | ● | 100 K | ||||
AC250V/10A | ● | ● | ● | 100 K | ||
AC250V/16A | ● | ● | ● | 100 K |